Sample Field IDs

<< Click to Display Table of Contents >>

Navigation:  Lab Reports > Details >

Sample Field IDs

Previous pageReturn to chapter overviewNext page

Samples can be submitted with a Field ID consisting of a combination of Location, Well, Depth and Date separated by a "_" or "/" delimiter. The individual components are extracted when imported into ESdat.  

 

Supported formats include:

 

Location/Depth

Locations can be included with depths, either as a single value or a range.  Either an _ or a / can be used as delimiters. Valid formats are:

BH12/1.1-1.3

BH12/1.1            

BH12_1.1-1.3

 

Location/Date

Either an _ or a / can be used as delimiters.

BH12/1 Jan 15

BH12/01.01.2015

BH12_20150101

 

Location/Depth/Date or Location/Date/Depth

Dates can be included, but is also provided specifically on most COC forms.  The date within the Field ID will be identified but ignored. Valid formats are:

BH12/1.1-1.3/12 Feb 08

BH12/12.02.08/1.1-1.3      

BH12_1.1-1.3_12.02.08

 

LocationWell_Date

MW01A_1 Jan 15

MW01A_20150101

MW01A_20/07/2017